Masimo Radical Signal Extraction Manuel de l'opérateur Page 1

Naviguer en ligne ou télécharger Manuel de l'opérateur pour Détecteurs de monoxyde de carbone (CO) Masimo Radical Signal Extraction. Masimo Radical Signal Extraction Operator`s manual [en] Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - Pulse Oximeter

Rad-8®Pulse OximeterSignal Extraction Pulse Oximeter OPERATOR’S MANUAL

Page 2

Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual 1-11overviewAbout This ManualThis manual explains how to set up and use the Rad-8 Pulse Oxime

Page 3

1-2 Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual1overviewWarnings, cautions and notesPlease read and follow any warnings, cautions and not

Page 4 - i

Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual 1-31overviewProduct DescriptionThe Rad-8 is a noninvasive, arterial oxygen saturation and pul

Page 5

1-4 Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual1overview1Pulse OximetrySpO2 GENERAL DESCRIPTIONPulse Oximetry is a continuous and noninva

Page 6

Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual 1-51overviewPRINCIPLE OF OPERATION (CONTINUED)The Rad-8 Pulse Oximeter uses a two-wavelength

Page 7

1-6 Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual1overview1SIGNAL EXTRACTION TECHNOLOGY (SET) FOR SpO2 MEASUREMENTSMasimo Signal Extraction

Page 8 - v

Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual 1-711overviewMASIMO SET DST

Page 10

Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual 2-122system descriptionIntroductionThe Rad-8 is designed for ease of operation. All pulse oxi

Page 11

2-2 Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual2system descriptionRAD-8 FRONT PANEL (VERTICAL MODEL)888888®888888RAD-8 FRONT PANEL (HORIZ

Page 12

Rad-8Pulse OximeterSignal Extraction Pulse OximeterOPERATOR’S MANUAL

Page 13 - Absorption Spectra

Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual 2-32system descriptionFront Panel Controls/IndicatorsCONTROL / INDICATORDESCRIPTION1AC Power

Page 14

2-4 Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual2system descriptionFront Panel Controls/Indicators continuedCONTROL / INDICATORDESCRIPTION

Page 15

Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual 2-52SYMBOLSThe following symbols are found on the pulse oximeter or packaging and are defined

Page 17

Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual 3-13setupIntroductionBefore the pulse oximeter can be used in a clinical setting, it needs to

Page 18

3-2 Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual3setupINITIAL BATTERY CHARGINGBefore use, the battery needs to be fully charged.To charge

Page 19

Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual 4-14operationIntroductionTo operate the Rad-8 system effectively, the device must be set up c

Page 20 - DESCRIPTION

4-2 Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual4operationGENERAL SETUP AND USE (CONTINUED)13. Verify the sensor alarms are functional.

Page 21 - RAD-8 REAR PANEL

Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual 4-34operationFACTORY DEFAULT AND USER CONFIGURABLE SETTINGSOPTIONFACTORY DEFAULT SETTINGSUSER

Page 22 - 5%-95% RH

4-4 Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual4operationSuccessful MonitoringThe following general points will aid in ensuring monitorin

Page 24

Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual 4-54operationNUMERIC DISPLAY - PULSE RATEThe Pulse Rate displayed on the Rad-8 Pulse Oximeter

Page 25 - HUMIDITY

4-6 Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual4operationACTIONS TO BE TAKENIf the SpO2 readings show significant differences, do the fo

Page 26

Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual 4-74operationSENSOR PLACEMENTIf the SpO2, readings are questionable or unavailable, do the fo

Page 27

4-8 Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual4operationLOW BATTERY AUDIBLE ALARMIf a low battery condition occurs during patient monito

Page 28

Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual 4-94operationNormal patient monitoringFRONT PANEL CONTROL OPERATIONSETUP MENUThis section giv

Page 29

4-10 Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual4SETUP MENU LEVEL 1 (CONTINUED)LED BRIGHTNESSThe Display screen and all active LED indica

Page 30

Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual 4-114operationSETUP MENU LEVEL 2 (CONTINUED)ALARM SILENCE BUTTONS

Page 31

4-12 Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual4SETUP MENU LEVEL 2 (CONTINUED) CLEAR TRENDThe Rad-8 only stores data in the trend memory

Page 32

Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual 4-134operationSENSITIVITY BUTTONS SETTIN

Page 33

4-14 Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual4SETUP MENU LEVEL 3 (ENTER BUTTON + DOWN BUTTON MENU SETTINGS)Setup Menu Level 3 contains

Page 34

Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual iThe Rad-8 Operating Instructions provide the necessary information for proper o

Page 35

Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual 4-154operationSETUP MENU LEVEL 3 - (CONTINUED)RAPID DESAT LIMITThe Rapid Desat Limit is desig

Page 36 - ALARM DELAY

4-16 Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual4SETUP MENU LEVEL 3 - (CONTINUED)DEFAULT SETTINGS BUTTONS

Page 37

Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual 4-174operationSETUP MENU LEVEL 3 - (CONTINUED)YEAR BUTTONS

Page 38 - SENSITIVITY

4-18 Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual4SETUP MENU LEVEL 3 (CONTINUED)DAY BUTTONS

Page 39 - + DOWN BUTTON MENU SETTINGS)

Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual 4-194operationSETUP MENU LEVEL 3 (CONTINUED)MINUTE BUTTONS

Page 40 - ALARM ON/OFF

4-20 Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual4SETUP MENU LEVEL 3 (CONTINUED)SERIAL OUTPUT BUTTONS

Page 41

Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual 4-214operationNURSE CALL BUTTONS SETTINGS I

Page 42

4-22 Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual4SETUP MENU LEVEL 4 (ENTER BUTTON + UP BUTTON MENU SETTINGS)Level 4 parameter/measurement

Page 43

Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual 4-234operationTrend Setup and UseINTRODUCTIONThe Rad-8 can store up to 72 hours of trend data

Page 44 - 3 (CONTINUED)

4-24 Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual4TREND DATA FORMATAfter a successful download of the trend data, a .out file will be crea

Page 45

Rad-8 Signal Extraction Pulse Oximeter Operator’s ManualiiSAFETY INFORMATION, WARNINGS, CAUTIONS AND NOTESThe Rad-8 Pulse Oximeter is designed to mini

Page 46

Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual 4-254operationHOME MODE OPERATIONThe device can be placed into the Home Mode to protect unqua

Page 48

Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual 5-15messagesAlarm identificationThe device visually and audibly indicates alarm conditions th

Page 49 - SAMPLE TREND OUTPUT

5-2 Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual5Alarm limitsCAUTION: TO ENSURE THAT ALARM LIMITS ARE APPROPRIATE FOR THE PATIENT BEING M

Page 50

Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual 5-35ALARM SILENCEAudible alarms may be silenced, while visual alarms remain active. The alarm

Page 51

5-4 Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual5messagesMESSAGESThe Rad-8 will indicate other data or system errors. Message conditions a

Page 52

Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual 5-55MESSAGES (CONTINUED)DISPLAY TYPE SOLUTIONNo Sensor ConnectedConnect sensor to cable.Senso

Page 54

Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual 6-16troubleshootingTroubleshootingThe following chart describes what to do if the Rad-8 syste

Page 55 - MESSAGES

6-2 Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual6Troubleshooting continued PROBLEM POSSIBLE CAUSE(S) RECOMMENDATIONSpO2 VALUES DO NOT CORR

Page 56 - MESSAGES (CONTINUED)

Rad-8 Signal Extraction Pulse Oximeter Operator’s ManualiiiSAFETY INFORMATION, WARNINGS, CAUTIONS AND NOTES If using Rad-8 during full body radiati

Page 57

Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual 7-17specificationsRad-8 specificationsPERFORMANCEMeasurement RangeArterial Oxygen Saturation

Page 58 - Troubleshooting

7-2 Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual7specificationsRad-8 specifications continuedPHYSICAL CHARACTERISTICSDimensions:8.2” x 6.

Page 59 - Troubleshooting continued

Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual 7-37Rad-8 specifications continuedspecifications3 Masimo SET technology with LNOP Adt sensor

Page 60 - ENVIRONMENTAL

7-4 Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual7specificationsSERIAL INTERFACE SETUP (CONTINUED)The pin-outs for the RS-232 connector are

Page 61 - PHYSICAL CHARACTERISTICS

Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual 8-18sensors & patient cablesIntroductionThis section covers the use and cleaning of Masim

Page 62

8-2 Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual8sensors & patient cablesMasimo SpO2 SensorsBefore use of any sensor or cable, careful

Page 63

Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual 8-38LNOP® REUSABLE SENSORS LNOP reusable sensors must be used in conjunction with Red PC cabl

Page 64 - Introduction

8-4 Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual8sensors & patient cablesLNCS® REUSABLE SENSORS LNCS reusable sensors must be used in

Page 65

Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual 8-58SENSOR ACCURACYRefer to Section 7, Specifications for SpO2 and pulse rate accuracy, unles

Page 67

Rad-8 Signal Extraction Pulse Oximeter Operator’s Manualivtable of contentsSECTION 1 - OVERVIEWAbout This Manual ...

Page 68

Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual 9-19service / maintenanceIntroductionThis chapter covers how to test the operation, properly

Page 69

9-2 Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual9Battery ServiceWARNING: THE BATTERY SHOULD BE INSTALLED AND/ OR REMOVED FROM THE RAD-8 BY

Page 70

Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual 9-39service / maintenancePerformance verification continued LED BRIGHTNESS:1. With the monit

Page 71 - 8 begins normal operation

9-4 Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual9Service and repairREPAIR POLICYMasimo or an authorized Service Department must perform wa

Page 72

Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual 9-59Sales & End-User License AgreementTHIS DOCUMENT IS A LEGAL AGREEMENT BETWEEN YOU (“PU

Page 73

9-6 Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual9service / maintenanceExclusions continuedTHIS WARRANTY, TOGETHER WITH ANY OTHER EXPRESS W

Page 74

Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual 9-79service / maintenanceRestrictions1. Copyright Restrictions: The Software and the accompa

Page 76

Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual 10-110AccessoriesAccessoriesPART NUMBER DESCRIPTION15111 Rad-8, Monitor Bag33134 Rad-8 Operat

Page 77

www.masimo.comInstruments and sensors containing Masimo SET technology are identified with the Masimo SET logo.33116/5303B-0209

Page 78 - Accessories

Rad-8 Signal Extraction Pulse Oximeter Operator’s Manualtable of contents vSECTION 4 - OPERATION (CONTINUED)Setup Menu Level 1 ...

Page 79 - 33116/5303B-0209

Rad-8 Signal Extraction Pulse Oximeter Operator’s ManualSECTION 6 - TROUBLESHOOTINGTroubleshooting ..............